Fanuc 0M-C
Set the following parameters on the machine
0002 = 00000001
0552 = 9 (For 2400 baud rate)
Set the setting data as follows
T.V.ON
= 0
(0: OFF, 1: ON)
ISO
= 1
I/O
= 0
To set the controller in the Drip feed mode
Enable parameter G127.5 in the ladder diagram
Select AUTO (DNC) mode on machine
Press Cycle start
Parameters for the various baud rates
For baud rates other than 2400 set as follows:
Baud rate
Parameter
50
100
110
150
200
300
600
1200
2400
4800
9600
1
2
3
4
5
6
7
8
9
10
11
Set the following parameters on the PC
General settings
Machine name
MCH-1
Control system
Fanuc
Machine ID
01
Time out (sec)
5
Control program start
M82
Control program end
M30
Is DNC required
Yes
DNC settings
Port Number
COM2 (or any free COM port)
Baud rate
2400
Data bits
7
Parity
Even
Stop bits
2
Handshake
Hardware
Filter null characters
Yes

 
Transmit settings
Transmit directory
Specify folder to store programs to be sent to machine from PC
Wait period at start of transmission
10.00
Wait period after transmitting program
8.0
Size of transmit packet
0
Delay period after each packet
0
Wait for XON before transmitting program
No
Drip feed
Off
Transmit comments?
Yes
Comment start character
(
Comment end character
)
Translation mode for CR
Transmit as CR
Translation mode for LF
Transmit as LF
Program start string
Program end string
Receive settings
Receive directory
Specify folder to store programs coming from machine
Wait period before receiving program
45.0
Wait period after receiving program
5.0
Transmit XON before transmitting program
No
Auto compare and save
Yes
Acknowledgements and errors
Transmit descriptive messages
Translation mode for CR
Ignore
Translation mode for LF
Save as CRLF
Acknowledgement / Error message start
%
O1234
Acknowledgement / Error message
M30
%
Ignore control characters other than CR-LF
Yes
To set the PC in the Drip feed mode
Handshake to = Software
Drip feed = ON
Cable connection
If the PC has 9 pin connector


 
If the PC has 25 pin connector