Mazak - M32
Set the following parameters on the machine
Parameter No.
Value
G19
2 (Baudrate)
G20
3 (Number of Stop bits)
G22
0 (Parity Check)
G23
3 (Number of data bits)
G24
1
G25
0
G26
0
G27
0 (ISO code CR output)
G28
0
G29
3 Type of Handshake)
To set the controller in the Drip feed mode
Drip feed is not available on this controller.
Parameters for the various baud rates
For baud rates other than 4800 set as follows:
Baud rate
Parameter
192000
9600
4800
2400
1200
600
300
110
0
1
2
3
4
5
6
7
Set the following parameters on the PC
General settings
Machine name
MCH-1
Control system
Mazak-M32
Machine ID
01
Time out (sec)
5
Control program start
M82
Control program end
M30
Is DNC required
Yes
DNC settings
Port Number
COM2 (or any free COM port)
Baud rate
4800
Data bits
7
Parity
Even
Stop bits
2
Handshake
Hardware
Filter null characters
Yes

 
Transmit settings
Transmit directory
Specify folder to store programs to be sent to machine from PC
Wait period at start of transmission
10.0
Wait period after transmitting program
5.0
Size of transmit packet
0
Delay period after each packet
0
Wait for XON before transmitting program
No
Drip feed
Off
Transmit comments?
Yes
Comment start character
(
Comment end character
)
Translation mode for CR
Transmit as CR
Translation mode for LF
Transmit as LF
Program start string
Program end string
Receive settings
Receive directory
Specify folder to store programs coming from machine
Wait period before receiving program
45.0
Wait period after receiving program
5.0
Transmit XON before transmitting program
No
Auto compare and save
Yes
Acknowledgements and errors
Transmit descriptive messages
Translation mode for CR
Ignore
Translation mode for LF
Save as CRLF
Acknowledgement / Error message start
%
:76
Acknowledgement / Error message end
M30
%
Ignore control characters other than CR-LF
Yes
To set the PC in the Drip feed mode
Drip feed is not available for this controller.
Cable connection
If the PC has 9 pin connector


 
If the PC has 25 pin connector